BQBLN - CARBON MONOXIDE IN AIR
- MSDS: BQBLN
- Manufacturer: GAS TECH INC JOHNSON INSTRUMENT DIV
- Product Name: CARBON MONOXIDE IN AIR
- National Stock Number: 6830-00N027864
Product Identification
Product ID:CARBON MONOXIDE IN AIR
MSDS Date:03/12/1990
FSC:6830
NIIN:00N027864
MSDS Number: BQBLN
Responsible Party
NEWARK, CA 94560-3431
US
Emergency Phone: 510-794-6200
Info Phone: 510-794-6200
Preparer: WILSON
Cage: 51906
Contractor
Telephone: 510-794-6200
Cage: 51906
Ingredients
CARBON MONOXIDE; (CARBONIC OXIDE)
CAS: 630-08-0
RTECS: FG3500000
Fraction By Weight: 0-6.5%VV
OSHA PEL 50 PPM
ACGIH TLV: 25 PPM; 9293
18.5-21.9 V/V
CAS: 7782-44-7
RTECS: RS2060000
Fraction By Weight: INGRED
74.3-80.1V/V
CAS: 7727-37-9
RTECS: QW9700000
Fraction By Weight: INGRED
ACGIH TLV: SIMPLE ASPHYXIANT
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: HEADACHE, NAUSEA, DIZZ,
WEAKNESS, RAPID BREATHING, UNCONSCIOUSNESS AND DEATH. CHRONIC
EFFECTS SIMILAR TO ACUTE EFFECTS SUCH AS HEADACHE, NAUSEA AND
DIZZINESS.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:EXPOSRE TO CO MAY AGGRAVATE HEART
DISEASE AND ARTERY DISEASE AND MAY CAUSE CHEST PAIN IN THOSE WITH
PRE-EXISTING HEART DISEASE.
First Aid
First Aid:INHAL: MOVE TO FRESH AIR & CALL EMERGENCY MED CARE; IF NOT
BREATHING, GIVE ARTF RESP; IF BREATHING IS DFCLT, GIVE O*2. INGEST:
NOT APPLICABLE. EYES: NOT APPLICABLE. SKIN: NOT APPLICABLE.
Fire Fighting
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:USE WHAT IS APPROP FOR SURROUNDING FIRE. SM
FIRES:DRY CHEM/CO*2 OR HALON. LG FIRES:H*2O SPRAY/FOG OR STD FOAM
IS RECOM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CYLINDER MAY EXPLODE IN HEAT OF FIRE.
WITHDRAW IMMED IN CASE OF RISING SOUND FROM VENTING SAFETY DEVICE.
Accidental Release
Spill Release Procedures:VENTILATE AREA.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN COOL, DRY AREA. DO NOT
PUNCTURE CYLINDER.
Other Precautions:EXPOSURE TO TEMPERATURE ABOVE 150F MAY OPERATE
EXCESS-PRESSURE VALVE.
Exposure Controls
Respiratory Protection:EMERGENCIES MAY REQUIRE NIOSH/MSHA APPROVED TYPE
N GAS MASK, OR PRESSURE DEMAND TYPE SCBA.
Ventilation:LOCAL EXHAUST/MECHANICAL: RECOMMENDED.
Protective Gloves:NOT REQUIRED.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
HCC:G3
Vapor Density:0.99-1.00
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS, ODORLESS COMPRESSED GAS.
Stability
Stability Indicator/Materials to Avoid:YES
NICKEL AND OXIDIZING MATERIALS, OIL IN HIGH PRESSURE EQUIPMENT.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO*2 AND OTHER OXIDES OF CARBON.
Disposal
Waste Disposal Methods:DISCHARGE GAS @ SLOW RATE. DO NOT INCINERATE.
EMPTY CYLINDERS MAY BE DISCARDED AS METAL REFUSE, OBSERVING
FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.